From 69bab6601692fd650b7e9f6f35b0e41d44d241f3 Mon Sep 17 00:00:00 2001
From: tqs <56479841@qq.com>
Date: 星期六, 03 十二月 2022 16:04:37 +0800
Subject: [PATCH] #

---
 src/main/java/com/zy/core/thread/SiemensCrnThread.java |   30 +++++++++++++++++-------------
 1 files changed, 17 insertions(+), 13 deletions(-)

diff --git a/src/main/java/com/zy/core/thread/SiemensCrnThread.java b/src/main/java/com/zy/core/thread/SiemensCrnThread.java
index 65343df..e0709ba 100644
--- a/src/main/java/com/zy/core/thread/SiemensCrnThread.java
+++ b/src/main/java/com/zy/core/thread/SiemensCrnThread.java
@@ -147,10 +147,11 @@
      */
     private void readStatus(){
         try {
-            OperateResultExOne<byte[]> result = siemensNet.Read("DB101.0", (short) 70);
+            OperateResultExOne<byte[]> result = siemensNet.Read("DB101.0", (short) 56);
             if (result.IsSuccess) {
                 if (null == crnProtocol) {
                     crnProtocol = new CrnProtocol();
+                    crnProtocol.setCrnNo(slave.getId());
                 }
                 crnProtocol.setMode(siemensNet.getByteTransform().TransInt16(result.Content, 0));
                 crnProtocol.setTaskNo(siemensNet.getByteTransform().TransInt16(result.Content, 2));
@@ -167,17 +168,19 @@
                 crnProtocol.setTemp3(siemensNet.getByteTransform().TransInt16(result.Content, 24));
                 crnProtocol.setTemp4(siemensNet.getByteTransform().TransInt16(result.Content, 26));
                 crnProtocol.setxSpeed(siemensNet.getByteTransform().TransInt16(result.Content, 28));
-                crnProtocol.setySpeed(siemensNet.getByteTransform().TransInt16(result.Content, 30));
-                crnProtocol.setzSpeed(siemensNet.getByteTransform().TransInt16(result.Content, 32));
-                crnProtocol.setxDistance(siemensNet.getByteTransform().TransInt16(result.Content, 34));
-                crnProtocol.setyDistance(siemensNet.getByteTransform().TransInt16(result.Content, 36));
-                crnProtocol.setxDuration(siemensNet.getByteTransform().TransInt16(result.Content, 38));
-                crnProtocol.setyDuration(siemensNet.getByteTransform().TransInt16(result.Content, 40));
+                crnProtocol.setySpeed(siemensNet.getByteTransform().TransInt16(result.Content, 32));
+                crnProtocol.setzSpeed(siemensNet.getByteTransform().TransInt16(result.Content, 36));
+                crnProtocol.setxDistance(siemensNet.getByteTransform().TransInt16(result.Content, 40));
+                crnProtocol.setyDistance(siemensNet.getByteTransform().TransInt16(result.Content, 44));
+                crnProtocol.setxDuration(siemensNet.getByteTransform().TransInt16(result.Content, 48));
+                crnProtocol.setyDuration(siemensNet.getByteTransform().TransInt16(result.Content, 52));
 
                 OutputQueue.CRN.offer(MessageFormat.format("銆恵0}銆慬id:{1}] <<<<< 瀹炴椂鏁版嵁鏇存柊鎴愬姛",DateUtils.convert(new Date()), slave.getId()));
 
                 // 澶嶄綅淇″彿
                 if (crnProtocol.getStatusType().equals(CrnStatusType.WAITING)) {
+                    log.error("-------------------------------------------绗竴姝ャ�乕鍫嗗灈鏈哄彿锛歿}, 宸ヤ綔鍙凤細{}, 杞借揣鍙�:{}]==>> 鐘舵�佷负10锛岀瓑寰呯‘璁わ紒锛�",
+                            slave.getId(),crnProtocol.getTaskNo(), crnProtocol.getLoaded()==1 ? "鏈夌墿" : "鏃犵墿");
                     if (resetFlag) {
                         if(crnProtocol.getTaskNo()==9999){
                             backHpFlag = false;
@@ -231,9 +234,9 @@
             log.error("鍫嗗灈鏈哄啓鍏ュ懡浠や负绌�");
             return false;
         }
-        convertRow(command);
+//        convertRow(command);
         command.setCrnNo(slave.getId());
-        short[] array = new short[12];
+        short[] array = new short[10];
         array[0] = command.getAckFinish();
         array[1] = command.getTaskNo();
         array[2] = command.getTaskMode();
@@ -243,14 +246,15 @@
         array[6] = command.getDestinationPosX();
         array[7] = command.getDestinationPosY();
         array[8] = command.getDestinationPosZ();
-        array[9] = command.getSourceStaNo();
-        array[10] = command.getDestinationStaNo();
-        array[11] = command.getCommand();
+//        array[9] = command.getSourceStaNo();
+//        array[10] = command.getDestinationStaNo();
+        array[9] = command.getCommand();
         OperateResult result = siemensNet.Write("DB100.0", array);
 
         if (command.getAckFinish() == 0) {
             short commandFinish = 1;
-            result = siemensNet.Write("DB100.22", commandFinish);
+            Thread.sleep(100L);
+            result = siemensNet.Write("DB100.18", commandFinish);
         }
 
         try {

--
Gitblit v1.9.1