From 36485d6d285438c2ccfa5c8352ab8b3fd831bed0 Mon Sep 17 00:00:00 2001
From: zhang <zc857179121@qq.com>
Date: 星期二, 07 四月 2026 16:56:42 +0800
Subject: [PATCH] 1

---
 zy-acs-cv/src/main/java/com/zy/core/thread/SiemensDevpThread.java |   35 ++++++++++++++++-------------------
 1 files changed, 16 insertions(+), 19 deletions(-)

diff --git a/zy-acs-cv/src/main/java/com/zy/core/thread/SiemensDevpThread.java b/zy-acs-cv/src/main/java/com/zy/core/thread/SiemensDevpThread.java
index e4a8a7d..1d424f4 100644
--- a/zy-acs-cv/src/main/java/com/zy/core/thread/SiemensDevpThread.java
+++ b/zy-acs-cv/src/main/java/com/zy/core/thread/SiemensDevpThread.java
@@ -15,6 +15,7 @@
 import com.zy.core.cache.MessageQueue;
 import com.zy.core.cache.OutputQueue;
 import com.zy.core.cache.SlaveConnection;
+import com.zy.core.constant.*;
 import com.zy.core.enums.SlaveType;
 import com.zy.core.enums.TaskType;
 import com.zy.core.model.DevpSlave;
@@ -134,7 +135,7 @@
     private void read() throws InterruptedException {
         List<Integer> staNos = slave.getStaNos();
         int staNoSize = staNos.size();
-        OperateResultExOne<byte[]> result = siemensS7Net.Read("DB100.0", (short) (staNoSize * 10));
+        OperateResultExOne<byte[]> result = siemensS7Net.Read(StationStatusField.ALL.buildAddress(), (short) (staNoSize * StationStatusField.ALL.getByteLength()));
         if (result.IsSuccess) {
             for (int i = 0; i < staNoSize; i++) {
                 Integer siteId = staNos.get(i); // 绔欑偣缂栧彿
@@ -144,9 +145,9 @@
                     staProtocol.setSiteId(siteId);
                     station.put(siteId, staProtocol);
                 }
-                staProtocol.setWorkNo((int) siemensS7Net.getByteTransform().TransUInt32(result.Content, i * 10));
-                staProtocol.setStaNo((int) siemensS7Net.getByteTransform().TransInt16(result.Content, i * 10 + 4));
-                boolean[] status = siemensS7Net.getByteTransform().TransBool(result.Content, i * 10 + 6, 2);
+                staProtocol.setWorkNo((int) siemensS7Net.getByteTransform().TransUInt32(result.Content, i * StationStatusField.ALL.getByteLength()));
+                staProtocol.setStaNo((int) siemensS7Net.getByteTransform().TransInt16(result.Content, i * StationStatusField.ALL.getByteLength() + 4));
+                boolean[] status = siemensS7Net.getByteTransform().TransBool(result.Content, i * StationStatusField.ALL.getByteLength() + 6, 2);
                 staProtocol.setAutoing(status[0]);  // 鑷姩
                 staProtocol.setLoading(status[1]);  // 鏈夌墿
                 staProtocol.setInEnable(status[2]); // 鍙叆
@@ -165,10 +166,10 @@
 
         //鏉$爜鎵弿鍣�
         List<Integer> barcodeArr = slave.getBarcodeArr();
-        OperateResultExOne<byte[]> result5 = siemensS7Net.Read("DB101.0", (short) (barcodeArr.size() * 8));
+        OperateResultExOne<byte[]> result5 = siemensS7Net.Read(DeviceField.BARCODE.buildAddress(), (short) (barcodeArr.size() * DeviceField.BARCODE.getByteLength()));
         if (result5.IsSuccess) {
             for (int i = 0; i < barcodeArr.size(); i++) {
-                String barcode = siemensS7Net.getByteTransform().TransString(result5.Content, i * 8, 8, "UTF-8");
+                String barcode = siemensS7Net.getByteTransform().TransString(result5.Content, i * DeviceField.BARCODE.getByteLength(), DeviceField.BARCODE.getByteLength(), "UTF-8");
                 BarcodeThread barcodeThread = (BarcodeThread) SlaveConnection.get(SlaveType.Barcode, barcodeArr.get(i));
                 if (Cools.isEmpty(barcode)) {
                     barcodeThread.clearBarcode();
@@ -181,22 +182,18 @@
             }
         }
 
-        OperateResultExOne<byte[]> resultError = siemensS7Net.Read("DB103.0", (short) (staNoSize * 2));
+        List<Integer> staNosError = slave.getStaNosError();
+        OperateResultExOne<byte[]> resultError = siemensS7Net.Read(DeviceField.DIMENSION_WORD.buildAddress(), (short) (staNoSize * DeviceField.DIMENSION_WORD.getByteLength()));
         if (resultError.IsSuccess) {
-            ArrayList<Integer> staNoError = new ArrayList<Integer>() {{
-                add(102);
-                add(201);
-                add(211);
-            }};
-            for (int i = 0; i < staNoError.size(); i++) {
-                Integer siteId = staNoError.get(i); // 绔欑偣缂栧彿
+            for (int i = 0; i < staNosError.size(); i++) {
+                Integer siteId = staNosError.get(i); // 绔欑偣缂栧彿
                 StaProtocol staProtocol = station.get(siteId);
                 if (null == staProtocol) {
                     staProtocol = new StaProtocol();
                     staProtocol.setSiteId(siteId);
                     station.put(siteId, staProtocol);
                 }
-                boolean[] status = siemensS7Net.getByteTransform().TransBool(resultError.Content, i * 2, 1);
+                boolean[] status = siemensS7Net.getByteTransform().TransBool(resultError.Content, i * DeviceField.DIMENSION_WORD.getByteLength(), DeviceField.DIMENSION_WORD.getByteLength());
                 staProtocol.setFrontErr(status[0]);// 鍓嶈秴闄�
                 staProtocol.setBackErr(status[1]);// 鍚庤秴闄�
                 staProtocol.setHighErr(status[2]);// 楂樿秴闄�
@@ -208,11 +205,11 @@
         }
 
         //plc鏁呴殰
-        OperateResultExOne<byte[]> resultErr2 = siemensS7Net.Read("DB25.0", (short) (staNoSize * 4));
+        OperateResultExOne<byte[]> resultErr2 = siemensS7Net.Read(PlcAlarmDefinition.ALL.buildAddress(), (short) (staNoSize * PlcAlarmDefinition.ALL.getByteLength()));
         if (resultErr2.IsSuccess) {
             for (int i = 0; i < staNoSize; i++) {
                 Integer siteId = staNos.get(i); // 绔欑偣缂栧彿
-                boolean[] status = siemensS7Net.getByteTransform().TransBool(resultErr2.Content, i * 4, 2);
+                boolean[] status = siemensS7Net.getByteTransform().TransBool(resultErr2.Content, i * PlcAlarmDefinition.ALL.getByteLength(), PlcAlarmDefinition.ALL.getByteLength());
                 StaProtocol staProtocol = station.get(siteId);
                 if (staProtocol != null) {
                     staProtocol.setBreakerErr(status[0]);
@@ -270,9 +267,9 @@
         //浠诲姟涓嬪彂娆℃暟
         int writeCount = 0;
         do {
-            write = siemensS7Net.Write("DB13." + index * 12, staProtocol.getWorkNo().shortValue());    // 宸ヤ綔鍙�
+            write = siemensS7Net.Write(TaskField.TASK_NUMBER.getAddressPattern() + PlcConstant.ADDRESS_CONCATENATION + (index * TaskField.ALL.getByteLength() + TaskField.TASK_NUMBER.getOffset()), staProtocol.getWorkNo().shortValue());    // 宸ヤ綔鍙�
             Thread.sleep(200);
-            write1 = siemensS7Net.Write("DB13." + (index * 12 + 6), staProtocol.getStaNo().shortValue());    // 鐩爣绔�
+            write1 = siemensS7Net.Write(TaskField.DEST_STATION.getAddressPattern() + PlcConstant.ADDRESS_CONCATENATION + (index * TaskField.ALL.getByteLength() + TaskField.DEST_STATION.getOffset()), staProtocol.getStaNo().shortValue());    // 鐩爣绔�
             if (write.IsSuccess && write1.IsSuccess) {
                 log.info("鍐欏叆杈撻�佺嚎鍛戒护鎴愬姛銆傝緭閫佺嚎plc缂栧彿={}锛岀珯鐐规暟鎹�={},鍐欏叆娆℃暟={}", slave.getId(), JSON.toJSON(staProtocol), writeCount);
                 break;

--
Gitblit v1.9.1