 |  |  |     private void write(StaProtocol staProtocol) throws InterruptedException { | 
 |  |  |         if (null == staProtocol) { | 
 |  |  |         if (staProtocol == null) { | 
 |  |  |             return; | 
 |  |  |         } | 
 |  |  |         ArrayList<Integer> staNos = getStaNo(); | 
 |  |  |  | 
 |  |  |         ArrayList<Integer> staNos = getStaNo(); | 
 |  |  |         int index = staNos.indexOf(staProtocol.getSiteId()); | 
 |  |  |  | 
 |  |  |         OperateResult writeResult; | 
 |  |  |         //任务下发次数 | 
 |  |  |         int writeCount = 0; | 
 |  |  |         //任务下发成功标识 | 
 |  |  |         boolean writeFlag = false; | 
 |  |  |         while(writeCount < 5){ | 
 |  |  |             OperateResult writeResult1 = siemensS7Net.Write("DB100." + index*6,  staProtocol.getWorkNo().intValue());    // 工作号 | 
 |  |  |             OperateResult writeResult2 = siemensS7Net.Write("DB100." + (index*6+4), staProtocol.getStaNo());    // 目标站 | 
 |  |  |             if(writeResult1.IsSuccess && writeResult2.IsSuccess){ | 
 |  |  |                 Thread.sleep(200); | 
 |  |  |                 OperateResultExOne<byte[]> readResult = siemensS7Net.Read("DB100." + index*6, (short)6); | 
 |  |  |                 if(readResult.IsSuccess){ | 
 |  |  |                     Integer workNo = siemensS7Net.getByteTransform().TransInt32(readResult.Content, 0); | 
 |  |  |                     short staNo = siemensS7Net.getByteTransform().TransInt16(readResult.Content, 4); | 
 |  |  |                     if(workNo.equals(staProtocol.getWorkNo().intValue()) && staProtocol.getStaNo().equals(staNo)){ | 
 |  |  |                         //任务命令写入成功 | 
 |  |  |                         writeFlag = true; | 
 |  |  |                         log.info("写入输送线命令后返回成功,并且回读成功。输送线plc编号={},{},写入次数={}", slave.getId(), JSON.toJSON(staProtocol), writeCount); | 
 |  |  |                         break; | 
 |  |  |                     } else {//返回结果是成功了,但是真实值不相同 | 
 |  |  |                         writeCount++; | 
 |  |  |                         OutputQueue.DEVP.offer(MessageFormat.format("【{0}】写入输送线命令后返回成功,但是读取任务值不一致。输送线plc编号={1},站点数据={2},写入次数={3}", | 
 |  |  |                                 slave.getId(), JSON.toJSON(staProtocol),writeCount)); | 
 |  |  |                         log.error("写入输送线命令后返回成功,但是读取任务值不一致。输送线plc编号={},{},写入次数={}", slave.getId(), JSON.toJSON(staProtocol), writeCount); | 
 |  |  |                     } | 
 |  |  |                 } else { | 
 |  |  |                     writeCount++; | 
 |  |  |                     OutputQueue.DEVP.offer(MessageFormat.format("【{0}】写入输送线命令后读取失败。输送线plc编号={1},站点数据={2},写入次数={3}", | 
 |  |  |                             slave.getId(), JSON.toJSON(staProtocol), writeCount)); | 
 |  |  |                     log.error("写入输送线命令后读取失败。输送线plc编号={},站点数据={},写入次数={}", slave.getId(), JSON.toJSON(staProtocol), writeCount); | 
 |  |  |         if (index == -1) { | 
 |  |  |             log.error("站点编号 {} 不在已知列表中,无法写入任务!", staProtocol.getSiteId()); | 
 |  |  |             return; | 
 |  |  |         } | 
 |  |  |  | 
 |  |  |         int writeCount = 0; // 任务下发尝试次数 | 
 |  |  |         boolean writeFlag = false; // 任务下发成功标记 | 
 |  |  |         String plcAddressWorkNo = "DB100." + index * 6; | 
 |  |  |         String plcAddressStaNo = "DB100." + (index * 6 + 4); | 
 |  |  |  | 
 |  |  |         while (writeCount < 5) { | 
 |  |  |             // **读取当前PLC状态,避免不必要的写入** | 
 |  |  |             OperateResultExOne<byte[]> readResult = siemensS7Net.Read(plcAddressWorkNo, (short) 6); | 
 |  |  |             if (readResult.IsSuccess) { | 
 |  |  |                 int currentWorkNo = siemensS7Net.getByteTransform().TransInt32(readResult.Content, 0); | 
 |  |  |                 short currentStaNo = siemensS7Net.getByteTransform().TransInt16(readResult.Content, 4); | 
 |  |  |  | 
 |  |  |                 if (currentWorkNo == staProtocol.getWorkNo().intValue() && currentStaNo == staProtocol.getStaNo()) { | 
 |  |  |                     log.info("站点 {} 当前状态已匹配,无需重复写入", staProtocol.getSiteId()); | 
 |  |  |                     return; | 
 |  |  |                 } | 
 |  |  |             } else { | 
 |  |  |             } | 
 |  |  |  | 
 |  |  |             // **清零并确认** | 
 |  |  |             if (!clearPLCData(plcAddressWorkNo, plcAddressStaNo, staProtocol.getSiteId())) { | 
 |  |  |                 writeCount++; | 
 |  |  |                 OutputQueue.DEVP.offer(MessageFormat.format("【{0}】写入输送线命令失败。输送线plc编号={1},站点数据={2},写入次数={3}", | 
 |  |  |                         slave.getId(), JSON.toJSON(staProtocol),writeCount)); | 
 |  |  |                 log.error("写入输送线命令失败。输送线plc编号={},站点数据={},写入次数={}", slave.getId(), JSON.toJSON(staProtocol), writeCount); | 
 |  |  |                 continue; // 重新尝试清零 | 
 |  |  |             } | 
 |  |  |             Thread.sleep(200); | 
 |  |  |  | 
 |  |  |             // **写入新任务** | 
 |  |  |             if (writeTaskToPLC(plcAddressWorkNo, plcAddressStaNo, staProtocol)) { | 
 |  |  |                 writeFlag = true; | 
 |  |  |                 log.info("输送线命令写入成功,PLC编号={},站点数据={},尝试次数={}", slave.getId(), JSON.toJSON(staProtocol), writeCount); | 
 |  |  |                 break; | 
 |  |  |             } | 
 |  |  |  | 
 |  |  |             log.warn("输送线命令写入失败,PLC编号={},站点数据={},尝试次数={}", slave.getId(), JSON.toJSON(staProtocol), writeCount); | 
 |  |  |             writeCount++; | 
 |  |  |         } | 
 |  |  |  | 
 |  |  |         //写命令尝试了5次还是失败了 | 
 |  |  |         if(!writeFlag){ | 
 |  |  |             staProtocol = station.get(staProtocol.getSiteId()); | 
 |  |  |             if (staProtocol.getWorkNo() == 0 && staProtocol.getStaNo() ==0) { | 
 |  |  |                 staProtocol.setPakMk(true); | 
 |  |  |             } | 
 |  |  |             OutputQueue.DEVP.offer(MessageFormat.format("【{0}】写入输送线命令尝试5次失败。输送线plc编号={1},站点数据={2}", slave.getId(), JSON.toJSON(staProtocol))); | 
 |  |  |             log.error("写入输送线命令尝试5次失败。输送线plc编号={},站点数据={}", slave.getId(), JSON.toJSON(staProtocol)); | 
 |  |  |  | 
 |  |  | //            //重新添加数据到任务队列 | 
 |  |  | //            boolean result = MessageQueue.offer(SlaveType.Devp, slave.getId(), new Task(2, staProtocol)); | 
 |  |  | //            read();//读取1次设备状态 | 
 |  |  |         } else { | 
 |  |  |             OutputQueue.DEVP.offer(MessageFormat.format("【{0}】 输送线命令下发成功 [id:{1}] >>>>> {2}", DateUtils.convert(new Date()), slave.getId(), JSON.toJSON(staProtocol))); | 
 |  |  |             log.info("输送线命令下发 [id:{}] >>>>> 命令下发成功: {}",  slave.getId(), JSON.toJSON(staProtocol)); | 
 |  |  |  | 
 |  |  | //            Integer siteId = staProtocol.getSiteId(); | 
 |  |  | //            staProtocol = station.get(siteId); | 
 |  |  | //            if ((siteId == 101 || siteId == 201)&&(staProtocol.getWorkNo() == 0 && staProtocol.getStaNo() ==0)) { | 
 |  |  | //                staProtocol.setPakMk(true); | 
 |  |  | //            } | 
 |  |  |         } | 
 |  |  |  | 
 |  |  |  | 
 |  |  |         // **写入失败处理** | 
 |  |  |         handleWriteFailure(staProtocol, writeFlag); | 
 |  |  |     } | 
 |  |  |  | 
 |  |  |     /** | 
 |  |  |      * 清零 PLC 数据并验证清零是否成功 | 
 |  |  |      */ | 
 |  |  |     private boolean clearPLCData(String plcAddressWorkNo, String plcAddressStaNo, int siteId) throws InterruptedException { | 
 |  |  |         siemensS7Net.Write(plcAddressWorkNo, 0); | 
 |  |  |         siemensS7Net.Write(plcAddressStaNo, (short) 0); | 
 |  |  |         Thread.sleep(100); // 等待PLC识别 | 
 |  |  |  | 
 |  |  |         OperateResultExOne<byte[]> readResult = siemensS7Net.Read(plcAddressWorkNo, (short) 6); | 
 |  |  |         if (readResult.IsSuccess) { | 
 |  |  |             int readWorkNo = siemensS7Net.getByteTransform().TransInt32(readResult.Content, 0); | 
 |  |  |             short readStaNo = siemensS7Net.getByteTransform().TransInt16(readResult.Content, 4); | 
 |  |  |             if (readWorkNo == 0 && readStaNo == 0) { | 
 |  |  |                 return true; // 清零成功 | 
 |  |  |             } | 
 |  |  |         } | 
 |  |  |  | 
 |  |  |         log.warn("站点 {} 清零失败,尝试重新清零...", siteId); | 
 |  |  |         return false; | 
 |  |  |     } | 
 |  |  |  | 
 |  |  |     /** | 
 |  |  |      * 写入新任务到 PLC 并验证是否成功 | 
 |  |  |      */ | 
 |  |  |     private boolean writeTaskToPLC(String plcAddressWorkNo, String plcAddressStaNo, StaProtocol staProtocol) throws InterruptedException { | 
 |  |  |         OperateResult writeResult1 = siemensS7Net.Write(plcAddressWorkNo, staProtocol.getWorkNo().intValue()); | 
 |  |  |         OperateResult writeResult2 = siemensS7Net.Write(plcAddressStaNo, staProtocol.getStaNo()); | 
 |  |  |  | 
 |  |  |         if (writeResult1.IsSuccess && writeResult2.IsSuccess) { | 
 |  |  |             Thread.sleep(200); // 等待 PLC 识别新值 | 
 |  |  |             OperateResultExOne<byte[]> readResult = siemensS7Net.Read(plcAddressWorkNo, (short) 6); | 
 |  |  |             if (readResult.IsSuccess) { | 
 |  |  |                 int workNo = siemensS7Net.getByteTransform().TransInt32(readResult.Content, 0); | 
 |  |  |                 short staNo = siemensS7Net.getByteTransform().TransInt16(readResult.Content, 4); | 
 |  |  |                 return workNo == staProtocol.getWorkNo().intValue() && staNo == staProtocol.getStaNo(); | 
 |  |  |             } | 
 |  |  |         } | 
 |  |  |         return false; | 
 |  |  |     } | 
 |  |  |  | 
 |  |  |     /** | 
 |  |  |      * 处理写入失败的情况 | 
 |  |  |      */ | 
 |  |  |     private void handleWriteFailure(StaProtocol staProtocol, boolean writeFlag) { | 
 |  |  |         if (!writeFlag) { | 
 |  |  |             StaProtocol currentStaProtocol = station.get(staProtocol.getSiteId()); | 
 |  |  |             if (currentStaProtocol.getWorkNo() == 0 && currentStaProtocol.getStaNo() == 0) { | 
 |  |  |                 currentStaProtocol.setPakMk(true); | 
 |  |  |             } | 
 |  |  |             OutputQueue.DEVP.offer(MessageFormat.format("【{0}】输送线命令尝试5次失败。PLC编号={1},站点数据={2}", | 
 |  |  |                     slave.getId(), JSON.toJSON(currentStaProtocol))); | 
 |  |  |             log.error("输送线命令尝试5次失败,PLC编号={},站点数据={}", slave.getId(), JSON.toJSON(currentStaProtocol)); | 
 |  |  |         } else { | 
 |  |  |             OutputQueue.DEVP.offer(MessageFormat.format("【{0}】输送线命令成功 [id:{1}] >>>>> {2}", | 
 |  |  |                     DateUtils.convert(new Date()), slave.getId(), JSON.toJSON(staProtocol))); | 
 |  |  |             log.info("输送线命令成功 [id:{}] >>>>> {}", slave.getId(), JSON.toJSON(staProtocol)); | 
 |  |  |         } | 
 |  |  |     } | 
 |  |  |  | 
 |  |  |  | 
 |  |  |     private void write2(StaProtocol staProtocol) throws InterruptedException { | 
 |  |  |         if (null == staProtocol) { | 
 |  |  |             return; |