| | | String workNoAddress = "DB1001." + (index * 20 + 100 + 2); |
| | | String staNoAddress = "DB1001." + (index * 20 + 100 + 4); |
| | | OperateResult write1 = siemensS7Net.Write(workNoAddress, workNo); // 工作号 |
| | | OperateResult write2 = siemensS7Net.Write(staNoAddress, staNo); // 目标站 |
| | | OperateResult write1 = null; // 工作号 |
| | | OperateResult write2 = null; // 目标站 |
| | | |
| | | if (!(write1.IsSuccess && write2.IsSuccess)) { |
| | | StaProtocol staProtocol = station.get(siteId); |
| | | if (staProtocol.getWorkNo() == 0 && staProtocol.getStaNo() ==0) { |
| | | staProtocol.setPakMk(true); |
| | | //任务下发次数 |
| | | int writeCount = 0; |
| | | do { |
| | | write1 = siemensS7Net.Write(workNoAddress, workNo); // 工作号 |
| | | write2 = siemensS7Net.Write(staNoAddress, staNo); // 目标站 |
| | | if ((write1.IsSuccess && write2.IsSuccess)) { |
| | | OperateResultExOne<byte[]> readResult = siemensS7Net.Read("DB1000." + (index * 40 + 100 + 2), (short) 4); |
| | | if (readResult.IsSuccess) { |
| | | short workNo2 = siemensS7Net.getByteTransform().TransInt16(readResult.Content, 0); |
| | | short staNo2 = siemensS7Net.getByteTransform().TransInt16(readResult.Content, 2); |
| | | if (workNo == workNo2 && staNo == staNo2) { |
| | | //任务命令写入成功 |
| | | log.info("写入输送线命令后返回成功,并且回读成功。输送线plc编号={},{},{},写入次数={}", siteId, JSON.toJSON(workNo), JSON.toJSON(staNo), writeCount); |
| | | return true; |
| | | } else {//返回结果是成功了,但是真实值不相同 |
| | | writeCount++; |
| | | log.error("写入输送线命令后返回成功,但是读取任务值不一致。输送线plc编号={},{},{},写入次数={}", siteId, JSON.toJSON(workNo), JSON.toJSON(staNo), writeCount); |
| | | } |
| | | } else { |
| | | writeCount++; |
| | | log.error("写入输送线命令后读取失败。输送线plc编号={},站点数据={},{},写入次数={}", siteId, JSON.toJSON(workNo), JSON.toJSON(staNo), writeCount); |
| | | } |
| | | }else { |
| | | writeCount++; |
| | | } |
| | | OutputQueue.DEVP.offer(MessageFormat.format("【{0}】写入输送线站点数据失败。输送线plc编号={1},站点数据={2}", device.getId(), JSON.toJSON(staProtocol))); |
| | | log.error("写入输送线站点数据失败。输送线plc编号={},站点数据={}", device.getId(), JSON.toJSON(staProtocol)); |
| | | } else { |
| | | OutputQueue.DEVP.offer(MessageFormat.format("【{0}】 输送线命令下发 [id:{1}] >>>>> {2},{3}", DateUtils.convert(new Date()), device.getId(), JSON.toJSON(workNo), JSON.toJSON(staNo))); |
| | | log.info("输送线命令下发 [id:{}] >>>>> 命令下发: {},{}", device.getId(), JSON.toJSON(workNo),JSON.toJSON(staNo)); |
| | | return true; |
| | | }while (writeCount < 5) ; |
| | | StaProtocol staProtocol = station.get(siteId); |
| | | if (staProtocol.getWorkNo() == 0 && staProtocol.getStaNo() ==0) { |
| | | staProtocol.setPakMk(true); |
| | | } |
| | | OutputQueue.DEVP.offer(MessageFormat.format("【{0}】写入输送线站点数据失败。输送线plc编号={1},站点数据={2}", device.getId(), JSON.toJSON(staProtocol))); |
| | | log.error("写入输送线站点数据失败。输送线plc编号={},站点数据={}", device.getId(), JSON.toJSON(staProtocol)); |
| | | return false; |
| | | } |
| | | |