@@ -54,7 +54,7 @@
    private int barcodeSize = 2;
    public IoModeType ioMode = IoModeType.NONE;
    public int[][] startSignal = new int[48][2];
    public int[][] startSignal = new int[48][3];
    public SiemensDevpThread(DevpSlave slave) {
        this.slave = slave;
@@ -205,12 +205,17 @@
        }
        Thread.sleep(200);
        OperateResultExOne<byte[]> result3 = siemensS7Net.Read("DB102.0", (short) 96);
        OperateResultExOne<byte[]> result4 = siemensS7Net.Read("DB108.0", (short) 96);
        //测试柜状态获取
        OperateResultExOne<byte[]> result3 = siemensS7Net.Read("DB38.0", (short) 96);
        //启动移库按钮
        OperateResultExOne<byte[]> result6 = siemensS7Net.Read("DB102.0", (short) 96);
        //消防报警
        OperateResultExOne<byte[]> result4 = siemensS7Net.Read("DB108.0", (short) 48);
        if(result3.IsSuccess) {
            for(int i=0; i<48; i++){
                startSignal[i][0] = siemensS7Net.getByteTransform().TransInt16(result3.Content, i*2);
                startSignal[i][1] = siemensS7Net.getByteTransform().TransInt16(result4.Content, i*2);
                startSignal[i][0] = siemensS7Net.getByteTransform().TransByte(result3.Content, i*2);//测试柜状态
                startSignal[i][1] = siemensS7Net.getByteTransform().TransBool(result4.Content, i)?1:0;//消防状态
                startSignal[i][2] = siemensS7Net.getByteTransform().TransInt16(result6.Content, i*2);//启动按钮状态
            }
        }
//        OperateResultExOne<Short> result2 = siemensS7Net.ReadInt16("DB200.0");
@@ -251,7 +256,8 @@
     */
    private void write103(String packNo){
        try{
            OperateResult write = siemensS7Net.Write("DB109.", packNo);
            OperateResult write = siemensS7Net.Write("DB109.0", packNo);
            if (!write.IsSuccess) {
                OutputQueue.DEVP.offer(MessageFormat.format("【{0}】写入输送线站点数据失败。输送线plc编号={1},站点数据={2}", slave.getId(), JSON.toJSON(packNo)));
                log.error("写入输送线站点数据失败。输送线plc编号={},站点数据={}", slave.getId(), JSON.toJSON(packNo));