| | | write(command); |
| | | break; |
| | | case 4: |
| | | siemensNet.Write("DB100.20", (short)task.getData()); |
| | | if(task.getData().equals("0")){ |
| | | siemensNet.Write("DB100.276", (short)0); |
| | | }else { |
| | | siemensNet.Write("DB100.276", (short)1); |
| | | } |
| | | |
| | | break; |
| | | default: |
| | | break; |
| | |
| | | */ |
| | | private void readStatus(){ |
| | | try { |
| | | OperateResultExOne<byte[]> result = siemensNet.Read("DB101.0", (short) 50); |
| | | OperateResultExOne<byte[]> result = siemensNet.Read("DB101.0", (short) 65); |
| | | if (result.IsSuccess) { |
| | | if (null == crnProtocol) { |
| | | crnProtocol = new CrnProtocol(); |
| | |
| | | crnProtocol.setTemp3(siemensNet.getByteTransform().TransInt16(result.Content, 24)); |
| | | crnProtocol.setTemp4(siemensNet.getByteTransform().TransInt16(result.Content, 26)); |
| | | crnProtocol.setxSpeed(siemensNet.getByteTransform().TransInt16(result.Content, 28)); |
| | | crnProtocol.setySpeed(siemensNet.getByteTransform().TransInt16(result.Content, 30)); |
| | | crnProtocol.setzSpeed(siemensNet.getByteTransform().TransInt16(result.Content, 32)); |
| | | crnProtocol.setxDistance(siemensNet.getByteTransform().TransInt16(result.Content, 34)); |
| | | crnProtocol.setyDistance(siemensNet.getByteTransform().TransInt16(result.Content, 36)); |
| | | crnProtocol.setxDuration(siemensNet.getByteTransform().TransInt16(result.Content, 38)); |
| | | crnProtocol.setyDuration(siemensNet.getByteTransform().TransInt16(result.Content, 40)); |
| | | crnProtocol.setySpeed(siemensNet.getByteTransform().TransInt16(result.Content, 32)); |
| | | crnProtocol.setzSpeed(siemensNet.getByteTransform().TransInt16(result.Content, 36)); |
| | | crnProtocol.setxDistance(siemensNet.getByteTransform().TransInt16(result.Content, 40)); |
| | | crnProtocol.setyDistance(siemensNet.getByteTransform().TransInt16(result.Content, 44)); |
| | | crnProtocol.setxDuration(siemensNet.getByteTransform().TransInt16(result.Content, 48)); |
| | | crnProtocol.setyDuration(siemensNet.getByteTransform().TransInt16(result.Content, 52)); |
| | | crnProtocol.setBarcodeResult(siemensNet.getByteTransform().TransBool(result.Content, 56)); |
| | | crnProtocol.setBarcode(siemensNet.getByteTransform().TransString(result.Content, 58,6,"UTF-8")); |
| | | |
| | | OutputQueue.CRN.offer(MessageFormat.format("【{0}】[id:{1}] <<<<< 实时数据更新成功",DateUtils.convert(new Date()), slave.getId())); |
| | | |
| | |
| | | log.error("堆垛机写入命令为空"); |
| | | return false; |
| | | } |
| | | convertRow(command); |
| | | //convertRow(command); |
| | | command.setCrnNo(slave.getId()); |
| | | short[] array = new short[12]; |
| | | array[0] = command.getAckFinish(); |
| | |
| | | array[10] = command.getDestinationStaNo(); |
| | | array[11] = command.getCommand(); |
| | | OperateResult result = siemensNet.Write("DB100.0", array); |
| | | |
| | | if (command.getAckFinish() == 0){ |
| | | OperateResult result2 = siemensNet.Write("DB100.20", command.getBarcode()); |
| | | } |
| | | if (command.getAckFinish() == 0) { |
| | | short commandFinish = 1; |
| | | result = siemensNet.Write("DB100.18", commandFinish); |