| | | write3((StaProtocol) task.getData()); |
| | | read(); |
| | | break; |
| | | // 侧面码盘完成上报wms成功后重置plc |
| | | case 4: |
| | | write4((StaProtocol) task.getData()); |
| | | read(); |
| | | break; |
| | | default: |
| | | break; |
| | | } |
| | |
| | | staProtocol.setPakMk(true); |
| | | } |
| | | } |
| | | } |
| | | |
| | | // 读侧面码盘完成信号 |
| | | OperateResultExOne<byte[]> resultMp = siemensS7Net.Read("DB79.362", (short) 4); |
| | | if (resultMp.IsSuccess) { |
| | | StaProtocol staProtocol207 = station.get(207); |
| | | StaProtocol staProtocol212 = station.get(212); |
| | | staProtocol207.setMpCompletedFlag(siemensS7Net.getByteTransform().TransInt16(resultMp.Content, 0)); |
| | | staProtocol212.setMpCompletedFlag(siemensS7Net.getByteTransform().TransInt16(resultMp.Content, 2)); |
| | | } |
| | | |
| | | // 读取正面条码 |
| | |
| | | } else { |
| | | |
| | | String[] split = barcode.split("#"); |
| | | int offset = 48 + (staNo - 201) * 24; |
| | | int offset = (staNo - 201) * 24; |
| | | byte[] bytes = new byte[(split.length + 1) * 6]; |
| | | for (int j = 0, k = 0; j < split.length; j++) { |
| | | String s = split[j]; |
| | |
| | | OperateResult writeResult3 = siemensS7Net.Write(addressPre + lev, staProtocol.getLev()); // 码盘层数 |
| | | if (writeResult1.IsSuccess && writeResult2.IsSuccess && writeResult3.IsSuccess) { |
| | | writeFlag = true; |
| | | log.info("码盘信息写入输送线命令后返回成功,并且回读成功。输送线plc编号={},{},写入次数={}", slave.getId(), JSON.toJSON(staProtocol), writeCount); |
| | | log.info("码盘信息写入输送线命令后返回成功【{},{},{},{}】,并且回读成功,写入次数={}", staProtocol.getSiteId(),staProtocol.getMp(),staProtocol.getLx(),staProtocol.getLev(), writeCount); |
| | | break; |
| | | } else { |
| | | writeCount++; |
| | |
| | | } |
| | | |
| | | //写命令尝试了5次还是失败了 |
| | | if (!writeFlag) { |
| | | //重新添加数据到任务队列 |
| | | MessageQueue.offer(SlaveType.Devp, 1, new Task(3, staProtocol)); |
| | | log.error("码盘信息写入输送线命令尝试5次失败重新推送队列。输送线plc编号={},站点数据={}", slave.getId(), JSON.toJSON(staProtocol)); |
| | | // if (!writeFlag) { |
| | | // //重新添加数据到任务队列 |
| | | // MessageQueue.offer(SlaveType.Devp, 1, new Task(3, staProtocol)); |
| | | // log.error("码盘信息写入输送线命令尝试5次失败重新推送队列。输送线plc编号={},站点数据={}", slave.getId(), JSON.toJSON(staProtocol)); |
| | | // } |
| | | } |
| | | |
| | | private void write4(StaProtocol staProtocol){ |
| | | |
| | | int offset = 0; |
| | | |
| | | switch (staProtocol.getSiteId()) { |
| | | case 207: offset = 362;break; |
| | | case 212: offset = 364 ;break; |
| | | default: |
| | | log.error("重置码盘信号站点有误:{}" , staProtocol.getSiteId()); |
| | | return; |
| | | } |
| | | |
| | | String addressPre = "DB79."; |
| | | |
| | | //任务下发次数 |
| | | int writeCount = 0; |
| | | while (writeCount < 5) { |
| | | OperateResult writeResult1 = siemensS7Net.Write(addressPre + offset, (short) 0); |
| | | if (writeResult1.IsSuccess) { |
| | | log.info("侧面码盘完成上报wms成功后重置信号写入输送线命令后返回成功【{}】,并且回读成功,写入次数={}", staProtocol.getSiteId(), writeCount); |
| | | break; |
| | | } else { |
| | | writeCount++; |
| | | log.error("侧面码盘完成上报wms成功后重置信号写入输送线命令失败。输送线plc编号={},站点数据={},写入次数={}", slave.getId(), JSON.toJSON(staProtocol), writeCount); |
| | | } |
| | | } |
| | | } |
| | | |