| | | private short heartBeatVal = 1; |
| | | |
| | | public static final ArrayList<Integer> staNos1 = new ArrayList<Integer>() {{ |
| | | add(100);add(101);add(102);add(103);add(104); |
| | | add(105);add(106);add(107); |
| | | add(101); |
| | | add(102); |
| | | add(103); |
| | | add(104); |
| | | add(105); |
| | | add(106); |
| | | }}; |
| | | |
| | | public static final ArrayList<Integer> staNos2 = new ArrayList<Integer>() {{ |
| | | // add(401);add(402); |
| | | }}; |
| | | |
| | | private Integer count=0; |
| | | private Integer count = 0; |
| | | |
| | | /** |
| | | * 条码数量 |
| | | */ |
| | | private int barcodeSize = 4; |
| | | private int barcodeSize = 3; |
| | | |
| | | /** |
| | | * 入出库模式 |
| | |
| | | */ |
| | | public IoModeType ioModeOf1F = IoModeType.NONE; |
| | | public IoModeType ioModeOf2F = IoModeType.NONE; |
| | | // public IoModeType ioMode = IoModeType.NONE; |
| | | // public IoModeType ioMode = IoModeType.NONE; |
| | | public IoModeType ioModeOf3F = IoModeType.NONE; |
| | | public IoModeType ioModeOf4F = IoModeType.NONE; |
| | | // public IoModeType ioMode = IoModeType.NONE; |
| | |
| | | switch (slave.getId()) { |
| | | case 1: |
| | | return staNos1; |
| | | case 2: |
| | | return staNos2; |
| | | default: |
| | | throw new CoolException("服务器异常"); |
| | | } |
| | |
| | | break; |
| | | // 写数据 ID+目标站 |
| | | case 2: |
| | | write((StaProtocol)task.getData()); |
| | | write((StaProtocol) task.getData()); |
| | | break; |
| | | default: |
| | | break; |
| | |
| | | * 初始化站点状态 |
| | | */ |
| | | private void initSite() { |
| | | count ++; |
| | | count++; |
| | | ArrayList<Integer> staNos = getStaNo(); |
| | | if(count > 10) { |
| | | if (count > 10) { |
| | | // 站点编号 |
| | | for (Integer siteId : staNos) { |
| | | StaProtocol staProtocol = station.get(siteId); |
| | |
| | | siemensS7Net.setRack(slave.getRack().byteValue()); |
| | | siemensS7Net.setSlot(slave.getSlot().byteValue()); |
| | | OperateResult connect = siemensS7Net.ConnectServer(); |
| | | if(connect.IsSuccess){ |
| | | if (connect.IsSuccess) { |
| | | result = true; |
| | | OutputQueue.DEVP.offer(MessageFormat.format( "【{0}】输送线plc连接成功 ===>> [id:{1}] [ip:{2}] [port:{3}] [rack:{4}] [slot:{5}]", DateUtils.convert(new Date()), slave.getId(), slave.getIp(), slave.getPort(), slave.getRack(), slave.getSlot())); |
| | | OutputQueue.DEVP.offer(MessageFormat.format("【{0}】输送线plc连接成功 ===>> [id:{1}] [ip:{2}] [port:{3}] [rack:{4}] [slot:{5}]", DateUtils.convert(new Date()), slave.getId(), slave.getIp(), slave.getPort(), slave.getRack(), slave.getSlot())); |
| | | log.info("输送线plc连接成功 ===>> [id:{}] [ip:{}] [port:{}]", slave.getId(), slave.getIp(), slave.getPort()); |
| | | } else { |
| | | OutputQueue.DEVP.offer(MessageFormat.format( "【{0}】输送线plc连接失败!!! ===>> [id:{1}] [ip:{2}] [port:{3}] [rack:{4}] [slot:{5}]", DateUtils.convert(new Date()), slave.getId(), slave.getIp(), slave.getPort(), slave.getRack(), slave.getSlot())); |
| | | OutputQueue.DEVP.offer(MessageFormat.format("【{0}】输送线plc连接失败!!! ===>> [id:{1}] [ip:{2}] [port:{3}] [rack:{4}] [slot:{5}]", DateUtils.convert(new Date()), slave.getId(), slave.getIp(), slave.getPort(), slave.getRack(), slave.getSlot())); |
| | | log.error("输送线plc连接失败!!! ===>> [id:{}] [ip:{}] [port:{}]", slave.getId(), slave.getIp(), slave.getPort()); |
| | | initSite(); |
| | | } |
| | |
| | | updateIoMode(); |
| | | ArrayList<Integer> staNos = getStaNo(); |
| | | int staNoSize = staNos.size(); |
| | | OperateResultExOne<byte[]> result = siemensS7Net.Read("DB100.0", (short) (staNoSize*4)); |
| | | OperateResultExOne<byte[]> result = siemensS7Net.Read("DB101.0", (short) (staNoSize * 8)); |
| | | if (result.IsSuccess) { |
| | | for (int i = 0; i < staNoSize; i++) { |
| | | Integer siteId = staNos.get(i); // 站点编号 |
| | |
| | | staProtocol.setSiteId(siteId); |
| | | station.put(siteId, staProtocol); |
| | | } |
| | | staProtocol.setWorkNo(siemensS7Net.getByteTransform().TransInt16(result.Content, i*4)); // 工作号 |
| | | staProtocol.setWorkNo((short) siemensS7Net.getByteTransform().TransInt32(result.Content, i * 8)); // 工作号 |
| | | |
| | | staProtocol.setStaNo(siemensS7Net.getByteTransform().TransInt16(result.Content, i*4 + 2)); // 目标站 |
| | | staProtocol.setStaNo(siemensS7Net.getByteTransform().TransInt16(result.Content, i * 8 + 4)); // 目标站 |
| | | |
| | | boolean[] status = siemensS7Net.getByteTransform().TransBool(result.Content, i * 8 + 6, 2); |
| | | staProtocol.setAutoing(status[0]); // |
| | | staProtocol.setLoading(status[1]); // 有物 |
| | | staProtocol.setInEnable(status[2]); // 可入 |
| | | staProtocol.setOutEnable(status[3]);// 可出 |
| | | staProtocol.setEmptyMk(status[4]); // 空板信号 |
| | | staProtocol.setFullPlt(status[5]); // 满托盘 |
| | | staProtocol.setHigh(status[6]); // 高库位 |
| | | staProtocol.setLow(status[7]); // 低库位 |
| | | if (!staProtocol.isPakMk() && !staProtocol.isLoading()) { |
| | | staProtocol.setPakMk(true); |
| | | } |
| | | } |
| | | } |
| | | Thread.sleep(200); |
| | | // OperateResultExOne<byte[]> result0 = siemensS7Net.Read("DB100.2", (short) (staNoSize*2)); |
| | | // if (result0.IsSuccess) { |
| | | // for (int i = 0; i < staNoSize; i++) { |
| | | // Integer siteId = staNos.get(i); // 站点编号 |
| | | // StaProtocol staProtocol = station.get(siteId); |
| | | // if (null == staProtocol) { |
| | | // staProtocol = new StaProtocol(); |
| | | // staProtocol.setSiteId(siteId); |
| | | // station.put(siteId, staProtocol); |
| | | // } |
| | | // staProtocol.setStaNo(siemensS7Net.getByteTransform().TransInt16(result0.Content, i*2)); // 目标站 |
| | | // } |
| | | // } |
| | | // Thread.sleep(200); |
| | | OperateResultExOne<byte[]> result1 = null; |
| | | if(slave.getId()==1) { |
| | | result1 = siemensS7Net.Read("DB102.0", (short) (staNoSize*2)); |
| | | if (result1.IsSuccess) { |
| | | for (int i = 0; i < staNoSize; i++) { |
| | | Integer siteId = staNos.get(i); // 站点编号 |
| | | boolean[] status = siemensS7Net.getByteTransform().TransBool(result1.Content, i*2, 1); |
| | | StaProtocol staProtocol = station.get(siteId); |
| | | staProtocol.setAutoing(status[0]); // 自动 |
| | | staProtocol.setLoading(status[1]); // 有物 |
| | | staProtocol.setInEnable(status[2]); // 可入 |
| | | staProtocol.setOutEnable(status[3]);// 可出 |
| | | staProtocol.setEmptyMk(status[4]); // 空板信号 |
| | | staProtocol.setFullPlt(status[5]); // 满托盘 |
| | | staProtocol.setHigh(status[6]); // 高库位 |
| | | staProtocol.setLow(status[7]); // 低库位 |
| | | |
| | | if (!staProtocol.isPakMk() && !staProtocol.isLoading()) { |
| | | staProtocol.setPakMk(true); |
| | | } |
| | | count = 0; |
| | | //扫码器 |
| | | OperateResultExOne<byte[]> result2 = siemensS7Net.Read("DB101.600.0", (short) (barcodeSize * 10)); |
| | | if (result2.IsSuccess) { |
| | | for (int i = 0; i < barcodeSize; i++) { |
| | | String barcode = siemensS7Net.getByteTransform().TransString(result2.Content, i * 10+2, 8, "UTF-8"); |
| | | BarcodeThread barcodeThread = (BarcodeThread) SlaveConnection.get(SlaveType.Barcode, i + 1); |
| | | if (!Cools.isEmpty(barcodeThread) && !barcodeThread.getBarcode().equals(barcode)) { |
| | | barcodeThread.setBarcode(barcode); |
| | | } |
| | | } |
| | | } else if(slave.getId()==2) { |
| | | // result1 = siemensS7Net.Read("DB100.100", (short) (staNoSize * 2)); |
| | | // if (result1.IsSuccess) { |
| | | // for (int i = 0; i < staNoSize; i++) { |
| | | // Integer siteId = staNos.get(i); // 站点编号 |
| | | // boolean[] status = siemensS7Net.getByteTransform().TransBool(result1.Content, i * 2, 1); |
| | | // StaProtocol staProtocol = station.get(siteId); |
| | | // staProtocol.setAutoing(status[0]); // 自动 |
| | | // staProtocol.setLoading(status[1]); // 有物 |
| | | // staProtocol.setInEnable(status[2]); // 可入 |
| | | // staProtocol.setOutEnable(status[3]);// 可出 |
| | | // staProtocol.setEmptyMk(status[4]); // 空板信号 |
| | | // staProtocol.setFullPlt(status[5]); // 满托盘 |
| | | // staProtocol.setHigh(status[6]); // 高库位 |
| | | // staProtocol.setLow(status[7]); // 低库位 |
| | | // |
| | | // if (!staProtocol.isPakMk() && !staProtocol.isLoading()) { |
| | | // staProtocol.setPakMk(true); |
| | | // } |
| | | // } |
| | | // count = 0; |
| | | // } |
| | | } |
| | | |
| | | Thread.sleep(200); |
| | | if(slave.getId()==1) { |
| | | OperateResultExOne<byte[]> result2 = siemensS7Net.Read("DB102.40", (short) (barcodeSize * 8)); |
| | | if (result2.IsSuccess) { |
| | | for (int i = 0; i < barcodeSize; i++) { |
| | | String barcode = siemensS7Net.getByteTransform().TransString(result2.Content, i * 8, 8, "UTF-8"); |
| | | BarcodeThread barcodeThread = (BarcodeThread) SlaveConnection.get(SlaveType.Barcode, i + 1); |
| | | if (!Cools.isEmpty(barcodeThread) && !barcodeThread.getBarcode().equals(barcode)) { |
| | | barcodeThread.setBarcode(barcode); |
| | | } |
| | | } |
| | | |
| | | } |
| | | } |
| | | |
| | | // OperateResultExOne<Short> result2 = siemensS7Net.ReadInt16("DB200.0"); |
| | | // if (result2.IsSuccess) { |
| | | // this.ioMode = IoModeType.get(result2.Content); |
| | | // } |
| | | //外形检测 |
| | | OperateResultExOne<byte[]> resultErr1 = siemensS7Net.Read("DB101.702.0", (short) (barcodeSize*6)); |
| | | if (resultErr1.IsSuccess) { |
| | | for (int i = 0; i < barcodeSize; i++) { |
| | | int sta = 0; |
| | | switch (i) { |
| | | case 0: |
| | | sta = 102; |
| | | break; |
| | | case 1: |
| | | sta = 104; |
| | | break; |
| | | case 2: |
| | | sta = 106; |
| | | break; |
| | | } |
| | | StaProtocol staProtocol1 = station.get(sta); |
| | | boolean[] status1 = siemensS7Net.getByteTransform().TransBool(resultErr1.Content, i*6, 1); |
| | | staProtocol1.setFrontErr(status1[0]); |
| | | staProtocol1.setBackErr(status1[1]); |
| | | staProtocol1.setHighErr(status1[2]); |
| | | staProtocol1.setLeftErr(status1[3]); |
| | | staProtocol1.setRightErr(status1[4]); |
| | | staProtocol1.setWeightErr(status1[5]); |
| | | staProtocol1.setBarcodeErr(status1[6]); |
| | | } |
| | | } |
| | | |
| | | if (result.IsSuccess && !Cools.isEmpty(result1) && result1.IsSuccess) { |
| | | |
| | | OutputQueue.DEVP.offer(MessageFormat.format("【{0}】[id:{1}] <<<<< 实时数据更新成功",DateUtils.convert(new Date()), slave.getId())); |
| | | if (!Cools.isEmpty(result) && result.IsSuccess) { |
| | | |
| | | OutputQueue.DEVP.offer(MessageFormat.format("【{0}】[id:{1}] <<<<< 实时数据更新成功", DateUtils.convert(new Date()), slave.getId())); |
| | | |
| | | // 根据实时信息更新数据库 |
| | | try { |
| | |
| | | * 写入 ID+目标站 =====> 单站点写入 |
| | | */ |
| | | private void write(StaProtocol staProtocol) throws InterruptedException { |
| | | if (null == staProtocol) { |
| | | if (staProtocol == null) { |
| | | return; |
| | | } |
| | | |
| | | ArrayList<Integer> staNos = getStaNo(); |
| | | int index = staNos.indexOf(staProtocol.getSiteId()); |
| | | short[] array = new short[2]; |
| | | array[0] = staProtocol.getWorkNo(); |
| | | array[1] = staProtocol.getStaNo(); |
| | | OperateResult write = siemensS7Net.Write("DB100." + index*4, array); |
| | | |
| | | // OperateResult write = siemensS7Net.Write("DB100.0" + index*4, staProtocol.getWorkNo()); // 工作号 |
| | | // Thread.sleep(500); |
| | | // OperateResult write1 = siemensS7Net.Write("DB100.2" + index*4+2, staProtocol.getStaNo()); // 目标站 |
| | | |
| | | if (!write.IsSuccess) { |
| | | staProtocol = station.get(staProtocol.getSiteId()); |
| | | if (staProtocol.getWorkNo() == 0 && staProtocol.getStaNo() ==0) { |
| | | staProtocol.setPakMk(true); |
| | | } |
| | | OutputQueue.DEVP.offer(MessageFormat.format("【{0}】写入输送线站点数据失败。输送线plc编号={1},站点数据={2}", slave.getId(), JSON.toJSON(staProtocol))); |
| | | log.error("写入输送线站点数据失败。输送线plc编号={},站点数据={}", slave.getId(), JSON.toJSON(staProtocol)); |
| | | } else { |
| | | OutputQueue.DEVP.offer(MessageFormat.format("【{0}】 输送线命令下发 [id:{1}] >>>>> {2}", DateUtils.convert(new Date()), slave.getId(), JSON.toJSON(staProtocol))); |
| | | log.info("输送线命令下发 [id:{}] >>>>> 命令下发: {}", slave.getId(), JSON.toJSON(staProtocol)); |
| | | if (index == -1) { |
| | | log.error("站点编号 {} 不在已知列表中,无法写入任务!", staProtocol.getSiteId()); |
| | | return; |
| | | } |
| | | |
| | | int writeCount = 0; // 任务下发尝试次数 |
| | | boolean writeFlag = false; // 任务下发成功标记 |
| | | String plcAddressWorkNo = "DB100." + index * 6; |
| | | String plcAddressStaNo = "DB100." + (index * 6 + 4); |
| | | Thread.sleep(100); |
| | | while (writeCount < 5) { |
| | | // **读取当前PLC状态,避免不必要的写入** |
| | | OperateResultExOne<byte[]> readResult = siemensS7Net.Read(plcAddressWorkNo, (short) 6); |
| | | if (readResult.IsSuccess) { |
| | | int currentWorkNo = siemensS7Net.getByteTransform().TransInt32(readResult.Content, 0); |
| | | short currentStaNo = siemensS7Net.getByteTransform().TransInt16(readResult.Content, 4); |
| | | |
| | | if (currentWorkNo == staProtocol.getWorkNo().intValue() && currentStaNo == staProtocol.getStaNo()) { |
| | | log.info("站点 {} 当前状态已匹配,无需重复写入", staProtocol.getSiteId()); |
| | | return; |
| | | } |
| | | } |
| | | |
| | | // **清零并确认** |
| | | if (!clearPLCData(plcAddressWorkNo, plcAddressStaNo, staProtocol.getSiteId())) { |
| | | writeCount++; |
| | | continue; // 重新尝试清零 |
| | | } |
| | | |
| | | // **写入新任务** |
| | | if (writeTaskToPLC(plcAddressWorkNo, plcAddressStaNo, staProtocol)) { |
| | | writeFlag = true; |
| | | log.info("输送线命令写入成功,PLC编号={},站点数据={},尝试次数={}", slave.getId(), JSON.toJSON(staProtocol), writeCount); |
| | | break; |
| | | } |
| | | |
| | | log.warn("输送线命令写入失败,PLC编号={},站点数据={},尝试次数={}", slave.getId(), JSON.toJSON(staProtocol), writeCount); |
| | | writeCount++; |
| | | } |
| | | |
| | | // **写入失败处理** |
| | | handleWriteFailure(staProtocol, writeFlag); |
| | | } |
| | | |
| | | // 更新入出库模式 |
| | |
| | | log.error("写入输送线3F入出库模式失败。输送线plc编号={}", slave.getId()); |
| | | } |
| | | } |
| | | if (this.ioModeOf4F != IoModeType.NONE) { |
| | | if (!siemensS7Net.Write("DB100.86", this.ioModeOf4F.id).IsSuccess) { |
| | | OutputQueue.DEVP.offer(MessageFormat.format("【{0}】写入输送线F4入出库模式失败。输送线plc编号={1}", slave.getId())); |
| | | log.error("写入输送线4F入出库模式失败。输送线plc编号={}", slave.getId()); |
| | | } |
| | | } |
| | | } |
| | | |
| | | /** |
| | | * 心跳 |
| | | */ |
| | | private void heartbeat(){ |
| | | private void heartbeat() { |
| | | if (heartBeatVal == 1) { |
| | | heartBeatVal = 2; |
| | | } else { |
| | |
| | | public static void main(String[] args) { |
| | | System.out.println(staNos1.indexOf(129)); |
| | | System.out.println(staNos1.size()); |
| | | for (int i = 0; i< staNos1.size(); i++) { |
| | | for (int i = 0; i < staNos1.size(); i++) { |
| | | // System.out.println(i*2); |
| | | // System.out.println(i*2 + 200); |
| | | // System.out.println(i); |
| | | } |
| | | int index = staNos1.indexOf(128); |
| | | System.out.println(index*2); |
| | | System.out.println(index*2 + 200); |
| | | System.out.println(index * 2); |
| | | System.out.println(index * 2 + 200); |
| | | } |
| | | |
| | | // public static void main(String[] args) throws Exception { |
| | |
| | | // System.out.println(JSON.toJSONString(devpThread.station)); |
| | | // |
| | | // } |
| | | /** |
| | | * 清零 PLC 数据并验证清零是否成功 |
| | | */ |
| | | private boolean clearPLCData(String plcAddressWorkNo, String plcAddressStaNo, int siteId) throws InterruptedException { |
| | | siemensS7Net.Write(plcAddressWorkNo, 0); |
| | | siemensS7Net.Write(plcAddressStaNo, (short) 0); |
| | | Thread.sleep(100); // 等待PLC识别 |
| | | |
| | | OperateResultExOne<byte[]> readResult = siemensS7Net.Read(plcAddressWorkNo, (short) 6); |
| | | if (readResult.IsSuccess) { |
| | | int readWorkNo = siemensS7Net.getByteTransform().TransInt32(readResult.Content, 0); |
| | | short readStaNo = siemensS7Net.getByteTransform().TransInt16(readResult.Content, 4); |
| | | if (readWorkNo == 0 && readStaNo == 0) { |
| | | return true; // 清零成功 |
| | | } |
| | | } |
| | | |
| | | log.warn("站点 {} 清零失败,尝试重新清零...", siteId); |
| | | return false; |
| | | } |
| | | |
| | | /** |
| | | * 写入新任务到 PLC 并验证是否成功 |
| | | */ |
| | | private boolean writeTaskToPLC(String plcAddressWorkNo, String plcAddressStaNo, StaProtocol staProtocol) throws InterruptedException { |
| | | OperateResult writeResult2 = siemensS7Net.Write(plcAddressStaNo, staProtocol.getStaNo()); |
| | | |
| | | OperateResult writeResult1 = siemensS7Net.Write(plcAddressWorkNo, staProtocol.getWorkNo().intValue()); |
| | | |
| | | if (writeResult1.IsSuccess && writeResult2.IsSuccess) { |
| | | Thread.sleep(200); // 等待 PLC 识别新值 |
| | | OperateResultExOne<byte[]> readResult = siemensS7Net.Read(plcAddressWorkNo, (short) 6); |
| | | if (readResult.IsSuccess) { |
| | | int workNo = siemensS7Net.getByteTransform().TransInt32(readResult.Content, 0); |
| | | short staNo = siemensS7Net.getByteTransform().TransInt16(readResult.Content, 4); |
| | | return workNo == staProtocol.getWorkNo().intValue() && staNo == staProtocol.getStaNo(); |
| | | } |
| | | } |
| | | return false; |
| | | } |
| | | |
| | | /** |
| | | * 处理写入失败的情况 |
| | | */ |
| | | private void handleWriteFailure(StaProtocol staProtocol, boolean writeFlag) { |
| | | if (!writeFlag) { |
| | | StaProtocol currentStaProtocol = station.get(staProtocol.getSiteId()); |
| | | if (currentStaProtocol.getWorkNo() == 0 && currentStaProtocol.getStaNo() == 0) { |
| | | currentStaProtocol.setPakMk(true); |
| | | } |
| | | OutputQueue.DEVP.offer(MessageFormat.format("【{0}】输送线命令尝试5次失败。PLC编号={1},站点数据={2}", |
| | | slave.getId(), JSON.toJSON(currentStaProtocol))); |
| | | log.error("输送线命令尝试5次失败,PLC编号={},站点数据={}", slave.getId(), JSON.toJSON(currentStaProtocol)); |
| | | } else { |
| | | OutputQueue.DEVP.offer(MessageFormat.format("【{0}】输送线命令成功 [id:{1}] >>>>> {2}", |
| | | DateUtils.convert(new Date()), slave.getId(), JSON.toJSON(staProtocol))); |
| | | log.info("输送线命令成功 [id:{}] >>>>> {}", slave.getId(), JSON.toJSON(staProtocol)); |
| | | } |
| | | } |
| | | |
| | | } |