whycq
2022-08-04 6a82697564dc4dd50e43fe74cd5ae305a7a18ede
src/main/java/com/zy/core/thread/SiemensCrnThread.java
@@ -38,6 +38,11 @@
    private CrnProtocol crnProtocol;
    private boolean resetFlag = false;
    /**
     * 堆垛机是否在回原点运动中标记
     */
    private boolean backHpFlag = false;
    public SiemensCrnThread(CrnSlave slave) {
        this.slave = slave;
    }
@@ -142,7 +147,7 @@
     */
    private void readStatus(){
        try {
            OperateResultExOne<byte[]> result = siemensNet.Read("DB101.0", (short) 70);
            OperateResultExOne<byte[]> result = siemensNet.Read("DB101.0", (short) 56);
            if (result.IsSuccess) {
                if (null == crnProtocol) {
                    crnProtocol = new CrnProtocol();
@@ -162,18 +167,21 @@
                crnProtocol.setTemp3(siemensNet.getByteTransform().TransInt16(result.Content, 24));
                crnProtocol.setTemp4(siemensNet.getByteTransform().TransInt16(result.Content, 26));
                crnProtocol.setxSpeed(siemensNet.getByteTransform().TransInt16(result.Content, 28));
                crnProtocol.setySpeed(siemensNet.getByteTransform().TransInt16(result.Content, 30));
                crnProtocol.setzSpeed(siemensNet.getByteTransform().TransInt16(result.Content, 32));
                crnProtocol.setxDistance(siemensNet.getByteTransform().TransInt16(result.Content, 34));
                crnProtocol.setyDistance(siemensNet.getByteTransform().TransInt16(result.Content, 36));
                crnProtocol.setxDuration(siemensNet.getByteTransform().TransInt16(result.Content, 38));
                crnProtocol.setyDuration(siemensNet.getByteTransform().TransInt16(result.Content, 40));
                crnProtocol.setySpeed(siemensNet.getByteTransform().TransInt16(result.Content, 32));
                crnProtocol.setzSpeed(siemensNet.getByteTransform().TransInt16(result.Content, 36));
                crnProtocol.setxDistance(siemensNet.getByteTransform().TransInt16(result.Content, 40));
                crnProtocol.setyDistance(siemensNet.getByteTransform().TransInt16(result.Content, 44));
                crnProtocol.setxDuration(siemensNet.getByteTransform().TransInt16(result.Content, 48));
                crnProtocol.setyDuration(siemensNet.getByteTransform().TransInt16(result.Content, 52));
                OutputQueue.CRN.offer(MessageFormat.format("【{0}】[id:{1}] <<<<< 实时数据更新成功",DateUtils.convert(new Date()), slave.getId()));
                // 复位信号
                if (crnProtocol.getStatusType().equals(CrnStatusType.WAITING)) {
                    if (resetFlag) {
                        if(crnProtocol.getTaskNo()==9999){
                            backHpFlag = false;
                        }
                        CrnCommand crnCommand = new CrnCommand();
                        crnCommand.setAckFinish((short)1);
                        if (write(crnCommand)) {